Features
Specifications
Water Inlet Requirements: Tap Water (inlet Water Pressure: 0.2 To 0.4 MPa, Water Temperature: 5 To 45℃)
Retention Rate: ≥ 99%
Water Production Quantity: 20L/h
Water Extraction Flow Rate (L/min): 1.2-2L/min
Highlight:

ASTM Standard Ultra Pure Reverse Osmosis System

,

20L/H Ultra Pure Reverse Osmosis System

,

USP Standard lab ro water system

Basic Infomation
Place of Origin: China
Brand Name: ZOOMAC
Certification: CE
Model Number: ZWM-BA1-20
Payment & Shipping Terms
Packaging Details: Wooden case packaging
Payment Terms: L/C, T/T
Supply Ability: 50 available for sale
Product Description

Intelligent integrated ultrapure water system, secondary RO system

 

1. The product is made of engineering plastic ABS material, which is corrosion-resistant, acid-resistant and alkali-resistant, preventing the machine from being corroded under strong acid or strong alkali conditions.

2. It adopts a newly developed true-color 7-inch touch screen with independent intellectual property rights. Technology is centered around people. The large interface enables great performance. It is equipped with a microcomputer full-automatic control system, multi-level menu operation, featuring high precision, strong anti-interference ability, and the entire operation process is digitalized.

3. With an ergonomic design and a water-electricity separation structure, it has a built-in hidden DC24V power supply. The working voltage is lower than the human safety voltage, which is convenient for maintenance and replacement and ensures safety even more.

4. The water quality of pure water and ultrapure water can be monitored in real time online, with both digital and curve displays. It is equipped with a USB interface, and the water quality data can be downloaded.

5. There are specially set two-level passwords for the factory and customers. All system settings are protected by passwords to prevent unauthorized changes.

6. The produced water meets or exceeds the requirements of ASTM, NCCLS, ISO or USP.

7. It has a specially set fixed-volume water extraction function (fixed volume: 0.05 - 99L).

8. The date and operating time are displayed online.

9. It has the functions of chip-type consumable lifespan alarm and reminder, eliminating customers' worries.

10. The water quality parameters of pure water and ultrapure water can be freely set, providing different water quality requirements for different customers.

11. Intelligent design: When the water quality of the produced pure water fails to reach the set parameter value, it will automatically flow back, which meets the requirements of water resource conservation and ensures that the pure water in the storage tank is qualified.

12. Intelligent design: When the water quality of the produced ultrapure water fails to meet the set parameter value, it will automatically flow back to ensure that customers can obtain high-quality ultrapure water.

13. The water level of the storage tank can be set digitally, and the water storage capacity can be adjusted according to the customer's daily water consumption. This prevents the decline in the quality of pure water caused by excessive storage that is not used up in time and long-term storage. 14. The automatic circulation function of ultrapure water ensures that the entire system is sterile. It also has functions such as self-check upon startup, water shortage protection alarm, automatic reset after a power outage, automatic shutdown when the pure water tank is full, ultra-low pressure protection, and UV lamp failure alarm.

15. The accessories are connected with imported quick connectors, which are convenient, fast, and easy to maintain.

16. It adopts the process of double-connected large-water-volume ultra-purification columns combined with imported Rohm and Haas resin, which is convenient for replacement and has a long service life.

17. The equipment has the function of upgrading water quality and quantity in the later stage (function upgrade).

18. The pretreatment, RO, and ultra-purification components adopt a modular independent structure, making maintenance and filter element replacement more convenient and complying with the GLP specification. The pure water pipelines and connectors have all obtained NSF certification.

19. There is a full-automatic RO membrane anti-scaling flushing function (flushing at an interval of 2 hours), and an overpressure alarm will be triggered when the membrane pressure exceeds the set value.

20. A high-end water tank with a conical round bottom is used, which is convenient for cleaning (it can be emptied) and is equipped with an air respirator to prevent bacteria from entering the water tank.